:CALCulate:MARKer[1]|2|3|4|5|6|7|8|9|10:MODE
NORMal|POSition|DELTa|FIXed|OFF
Marker Mode
Function
This command sets the marker mode.
Command
:CALCulate:MARKer[n]:MODE <mode>
Parameter
<n>
Marker number
1
Marker 1
2
Marker 2
3
Marker 3
4
Marker 4
5
Marker 5
6
Marker 6
7
Marker 7
8
Marker 8
9
Marker 9
10
Marker 10
When omitted:
Marker 1
<mode>
Marker mode
NORMal|POSition
Normal marker
DELTa
Delta marker
FIXed
Fixed marker
OFF
Not displaying any marker
Default
Off (Normal only in Marker1)
Details
This command is not available during Spurious Emission measurement
and when Displayed Segment Mode is Auto.
Not available during Spectrum Emission Mask measurement.
When the N dB Bandwidth measurement function is set to On, the
currently active maker is set to normal.
Example of Use
To set the mode of the marker 1 to delta marker.
CALC:MARK:MODE DELT