2.14 Spurious Emission Measurement Function
2-777
2
SCPI Device Message Details
:CALCulate:SPURious[:RANGe][:LIST]:LIMit:ABSolute[:UPPer]:DATA:STOP?
Spurious Emission Limit Stop Level Query
Function
This command queries the absolute level limit of the stop frequency in
each segment for the Spurious Emission measurement.
Query
:CALCulate:SPURious[:RANGe][:LIST]:LIMit:ABSolute[:UPPer
]:DATA:STOP?
Response
<ampl_n>
Parameter
<ampl_n>
Absolute level limit of stop frequency of Segment
n
Range –200 dBm to 50 dBm
Resolution 0.01 dB
Suffix code None. Value is returned in dBm units.
Example of Use
To set the absolute level limit of the stop frequency in each segment.
CALC:SPUR:LIM:ABS:DATA:STOP?
>
−13.00,−13.00,−13.00,−13.00,−13.00,−13.00,-10.00,-10.00,
−13.00,−13.00,−13.00,−13.00,−13.00,−13.00,-10.00,-10.00,
−13.00,−13.00,−13.00,−13.00