To set Integrate BW of the offset automatically.
SEM:OFFS:LIST:BAND:INT:AUTO
ON,ON,ON,ON,ON,ON,ON,ON,ON,ON,ON,ON
SEM:OFFS:LIST:BAND:INT:AUTO?
> 1,1,1,1,1,1,1,1,1,1,1,1
SEM:OFFS:LIST:BAND:VID/SEM:OFFS:LIST:BAND:VID?
Spectrum Emission Mask Offset Video Bandwidth
Function
This command sets the video bandwidth (VBW) of the offset for Spectrum
Emission Mask measurement.
Command
SEM:OFFS:LIST:BAND:VID
bandwidth_1[,bandwidth_2[,bandwidth_3[,bandwidth_4[,band
width_5[,bandwidth_6[,bandwidth_7[,bandwidth_8[,bandwidt
h_9[,bandwidth_10[,bandwidth_11[,bandwidth_12]]]]]]]]]]]
Query
SEM:OFFS:LIST:BAND:VID?
Response
bandwidth_1,bandwidth_2,bandwidth_3,bandwidth_4,bandwidt
h_5,bandwidth_6,bandwidth_7,bandwidth_8,bandwidth_9,band
width_10,bandwidth_11,bandwidth_12
Returns a value of Hz units, without a suffix code.
Returns OFF when set to Off.
Parameter
bandwidth_n
Video bandwidth of Offset-n (VBW)
Range/Resolution 1 Hz to 10 MHz (1-3 sequence), 5 kHz
Suffix code HZ,KHZ,KZ,MHZ,MZ,GHZ,GZ
Hz is used when omitted.
OFF
Sets VBW to Off.
Details
The setting range of this function is limited depending on the settings of
other parameters. Refer to
MS2690A/MS2691A/MS2692A Signal
Analyzer Operation Manual (Spectrum Analyzer Function Operation)
or
MS2830A/MS2840A Signal Analyzer Operation Manual (Spectrum
Analyzer Function Operation)
for details.