MKPX/MKPX?
Peak Search Resolution
Function
This command sets the resolution for detecting the peak point.
Command
MKPX level
Query
MKPX?
Response
level
No suffix code, in dB units, 0.001 dB
Parameter
level
Peak point detection resolution
Range 0.001 to 100.000 dB (Log Scale)
0.01 to 100.00% (Lin Scale)
Suffix code DB
dB is used even when omitted.
Details
This command is not available during the Spurious Emission
measurement and when Displayed Segment Mode is set to Auto.
This command is disabled during the Spectrum Emission Mask
measurement.
Example of Use
To set the peak point detection resolution to 12.345 dB.
MKPX 12.345DB
MKPX 12.345
MKPX?
> 12.345