2
SCPI Device Message Details
Example of Use
To query the noise canceling function On/Off state.
ACP:CORR:NOIS?
> 0
Related command
This command has the same function as the following command.
:CALCulate:ACPower:CORRection:NOISe[:AUTO]?
:CALCulate:ACPower:CORRection:NOISe[:AUTO]?
Adjacent Channel Power Noise Cancel Query
Function
This command queries whether to apply the noise canceling function.
Refer to
[:SENSe]:ACPower:CORRection:NOISe[:AUTO]?.
Related command
This command has the same function as the following command.
[:SENSe]:ACPower:CORRection:NOISe[:AUTO]?
[:SENSe]:ACPower:OFFSet[1]:BANDwidth[:INTegration] <freq>
Adjacent Channel Power Offset Channel Bandwidth
Function
This command sets the Offset Channel bandwidth for Adjacent Channel
Power measurement.
Command
[:SENSe]:ACPower:OFFSet[1]:BANDwidth[:INTegration] <freq>
Parameter
<freq>
Offset Channel bandwidth
Range 1 to 1000000000 Hz
Resolution 1 Hz
Suffix code HZ,KHZ,KZ,MHZ,MZ,GHZ,GZ
Hz is used when omitted.
Default 3.84 MHz