Chapter 2 SCPI Device Message Details
2-154
:CALCulate:MARKer[1]|2|3|4|5|6|7|8|9|10:FCOunt:GATetime <time>
Frequency Counter Gate Time
Function
This command sets the counter gate time for frequency counter.
Command
:CALCulate:MARKer[n]:FCOunt:GATetime <time>
Parameter
<n>
Marker number
1
Marker 1
2
Marker 2
3
Marker 3
4
Marker 4
5
Marker 5
6
Marker 6
7
Marker 7
8
Marker 8
9
Marker 9
10
Marker 10
When omitted: Marker 1
<time>
Center time of zone marker
Range 100 µs to 1 s
Resolution 50 µs
Suffix code NS, US, MS, S
S is used when the suffix code is omitted.
Details
This command is not available when frequency counter is set to Off.
The setting value is shared by all the markers.
Example of Use
To set the counter gate time for frequency counter to 100 ms.
CALC:MARK:FCO:GAT 100MS