Native Device Message Details
4-321
4
Native Device Message Details
SWE:EGAT:HOLD:STAT/SWE:EGAT:HOLD:STAT?
Gate Hold On/Off
Function
This command switches On/Off the function to disable gate input for a
set time, from the first gate input signal until the next gate signal input,
during gate sweep.
Command
SWE:EGAT:HOLD:STAT switch_com
Query
SWE:EGAT:HOLD:STAT?
Response
switch_res
Parameter
switch_com
Sets Gate Hold to On/Off.
ON|1
Sets Gate Hold to On.
OFF|0
Sets Gate Hold to Off.
switch_res
Gate Hold On/Off
1
Gate Hold is On.
0
Gate Hold is Off.
Details
This command is not available for MS269x Series.
The Gate Sweep (On/Off) function is automatically set to On when this
function is set to On.
Example of Use
To set the gate input disable time setting to On.
SWE:EGAT:HOLD:STAT ON
SWE:EGAT:HOLD:STAT?
> 1