Native Device Message Details
4-169
4
Native Device Message Details
Example of Use
To set the active marker mode to delta.
MKR 1
MKR?
> 1
MKRL
Marker to Reference Level
Function
This command sets the marker level to the reference level.
Command
MKRL
Details
This command is not available in the following cases:
When the marker mode is set to Off.
During the Spurious Emission measurement and when the Displayed
Segment Mode is set to Auto.
During the Spectrum Emission Mask measurement.
Example of Use
To set the marker level to the reference level.
MKRL

Table of Contents