Native Device Message Details
4-362
Details
This function writes and queries positive detection trace data when the
detection mode is Positive & Negative (Normal mode).
This command is not available in the following cases:
During the Spectrum Emission Mask measurement.
During the Spectrum Emission measurement.
Example of Use
To set 20 dBm at the 1st point and 21 dBm at the 2nd point.
XMB 1,-20000
XMB 2,-21000
XMB? 1,2
> -20000,-21000
XMC/XMC?
Write and Query Trace Data (Trace C)
Function
This command writes and queries the trace data of Trace C in ASCII
format.
Command
XMC wpoint,data
Query
XMC? start,number
Response
data1,data2,...
Parameter
wpoint
Specify the writing position as the number of
displayed points from the left edge of the screen.
Range 0 to 10, 20, 40, 50, 100, 200, 250, 400, 500,1000,
2000, 5000, 10000, 30000 (MS269xA Only)
data
Level data to be written
Resolution 0.001 dB units (At log scale)
{ Voltage value (V)/Reference level(V) }
×
10000
(At linear scale)