SWE:EGAT:VIEW:POIN/SWE:EGAT:VIEW:POIN?
Gate View Trace Point
Function
This command sets the number of trace display points for Gate View.
This parameter and the one for setting the number of trace display
points for time axis measurement reference the same value.
Command
SWE:EGAT:VIEW:POIN integer
Query
SWE:EGAT:VIEW:POIN?
Response
integer
Parameter
integer
Number of trace display points
11
11 points
21
21 points
41
41 points
51
51 points
101
101 points
201
201 points
251
251 points
401
401 points
501
501 points
1001
1001 points
2001
2001 points
5001
5001 points
10001
10001 points
30001
30001 points (MS269xA Only)
Details
This command is not available when Gate View is set to Off.
Example of Use
To set the number of trace display points to 2001.
SWE:EGAT:VIEW:POIN 2001
SWE:EGAT:VIEW:POIN?
> 2001