Chapter
Native Device Message Details
4-305
4
Native Device Message Details
SPUR:TDOM:BAND:VID:COUP/SPUR:TDOM:BAND:VID:COUP?
Spurious Emission Couple Segment VBW
Function
This command enables/disables the function that the value set in
Segment Setup is automatically set to VBW when performing Time
Domain Measurement.
Command
SPUR:TDOM:BAND:VID:COUP
switch_1_com,switch_2_com,switch_3_com,switch_4_com,swit
ch_5_com,switch_6_com,switch_7_com,switch_8_com,switch_9
_com,switch_10_com,switch_11_com,switch_12_com,switch_13
_com,switch_14_com,switch_15_com,switch_16_com,switch_17
_com,switch_18_com,switch_19_com,switch_20_com
Query
SPUR:TDOM:BAND:VID:COUP?
Response
switch_1_res,switch_2_res,switch_3_res,switch_4_res,swit
ch_5_res,switch_6_res,switch_7_res,switch_8_res,switch_9
_res,switch_10_res,switch_11_res,switch_12_res,switch_13
_res,switch_14_res,switch_15_res,switch_16_res,switch_17
_res,switch_18_res,switch_19_res,switch_20_res
Parameter
switch_n_com
Shared setting On/Off
ON|1
On
OFF|0
Off
switch_n_res
Shared setting On/Off
1
On
0
Off
Example of Use
To enable/disable the function that the value set in Segment Setup is
automatically set to VBW when performing Time Domain measurement.
SPUR:TDOM:BAND:VID:COUP
ON,ON,ON,ON,OFF,OFF,ON,ON,ON,ON,ON,ON,ON,ON,OFF,OFF,ON,O
N,ON,ON
SPUR:TDOM:BAND:VID:COUP?
> 1,1,1,1,0,0,1,1,1,1,1,1,1,1,0,0,1,1,1,1

Table of Contents

Other manuals for Anritsu MS2840A

Related product manuals