[:SENSe]:TOI:ZSPan:BANDwidth|BWIDth[:RESolution] <freq>
TOI Zero Span Measurement Resolution Bandwidth
Function
This command sets the resolution bandwidth for the Zero Span
Measurement in the TOI measurement.
Command
[:SENSe]:TOI:ZSPan:BANDwidth|BWIDth[:RESolution] <freq>
Parameter
<freq>
Resolution bandwidth for the Zero Span
Measurement in the TOI measurement
[MS269xA]
Range/Resolution 30 Hz to 31.25 MHz
Set to any of 30 Hz to 3 MHz (1-3 sequence), 50
kHz, 5 MHz, 10 MHz, 20 MHz, and 31.25 MHz.
[MS2830A]
[MS2840A]
Range/Resolution 30 Hz to 31.25 MHz
Set to any of 30 Hz to 3 MHz (1-3 sequence), 500
Hz, 50 kHz, 2 MHz, 5 MHz, 10 MHz, 20 MHz or
31.25 MHz.
[Common]
Suffix code HZ, KHZ, KZ, MHZ, MZ, GHZ, GZ
Hz is used when omitted.
Default Value set in RBW Auto
Example of Use
To set the resolution bandwidth for the Zero Span Measurement.
TOI:ZSP:BAND 1MHZ