Chapter 2 SCPI Device Message Details
2-256
[:SENSe]:SWEep:TIME:AUTO OFF|ON|0|1
Sweep Time Auto/Manual
Function
This command enables/disables the automatic sweep time setting
function. Each parameter is specified in accordance with the
already-specified frequency axis or time axis measurement.
Command
[:SENSe]:SWEep:TIME:AUTO <switch>
Parameter
<switch>
Automatic sweep time setting function On/Off
0|OFF
Disables the automatic sweep time setting
function.
1|ON
Enables the automatic sweep time setting
function (Default).
Details
Fixed to Auto when in FFT measurement (MS2830A, MS2840A).
This command is not available during the Spectrum Emission Mask or
the Spurious Emission measurement.
This command is not available when Internal Signal Generator Control
On/Off is On.
Example of Use
To enable the automatic sweep time setting function.
SWE:TIME:AUTO ON
Related command
This command has the same function as the following commands.
[:SENSe]:ACPower:SWEep:TIME:AUTO
[:SENSe]:CHPower:SWEep:TIME:AUTO
[:SENSe]:OBWidth:SWEep:TIME:AUTO