Chapter
Native Device Message List
3-6
Table 3.2-1 Application common device messages (Cont’d)
Function Command Query Response Remarks
Hard Copy Mode
PMOD format PMOD? format
format
: Specifies file format
=
BMP | PNG
PMOD
PMOD?
BMP
END Event Status Enable Register
ESE2 n ESE2? byte
byte
= Status bit
bit7
: Not used
bit6
: End Max/Min Hold
bit5
: End Measure
bit4
: End Average
bit3
: Not used
bit2
: Not used
bit1
: Not used
bit0
: End Sweep
END Event Status Register
--- ESR2? byte
Calibration
CAL mode --- ---
mode
: Calibration mode
= ALL | LEVEL | LOLEAK_SUPPRESS
| BAND
Asynchronous command
Pre-selector Auto Tune
PRESEL AUTO --- ---
Pre-selector Bias Reset
PRESEL PRESET
---
---
Pre-selector Bias
PRESEL bias PRESEL? bias
bias
= Bias value of pre-selector
= 128 to 127
Micro Wave Preselector Bypass
POW:MW:PRES switch POW:MW:PRES? status
switch = ON|OFF|1|0
status = 1|0