3-46
Table 3.10.7-1 Spurious Emission Measurement function setting messages (Contd)
Function Command Query Response Remarks
Displayed Restart Query
--- DISP:SPUR:SEGM:REST? switch
switch :
= 1|0
Time Domain Measurement
SPUR:TDOM:SPAN:ZERO
switch_com
SPUR:TDOM:SPAN:ZERO? switch_res
switch_com :
= ON|OFF|1|0
Fail Stop
SPUR:FST switch_com SPUR:FST? switch_res
switch_com :
= ON|OFF|1|0
Edit Segment Number
SPUR:SEGM:NUMB
integer
SPUR:SEGM:NUMB? integer
Segment On/Off
SPUR:SEGM:STAT
switch_n_com
SPUR:SEGM:STAT? switch_n_res
n :1 to 20
switch_n_com :
= ON|OFF|1|0
Spurious Emission Start Frequency
SPUR:FREQ:STAR
freq_n
SPUR:FREQ:STAR? freq_n
n :1 to 20
Spurious Emission Stop Frequency
SPUR:FREQ:STOP
freq_n
SPUR:FREQ:STOP? freq_n
n :1 to 20
Reference Level Settings
DISP:SPUR:VIEW:WIND
:TRAC:Y:RLEV real_n
DISP:SPUR:VIEW:WIND:
TRAC:Y:RLEV?
real_n
n :1 to 20
Spurious Emission Attenuator
SPUR:ATT
rel_ampl_n|AUTO
SPUR:ATT? rel_ampl_n
n :1 to 20