EasyManua.ls Logo

Anritsu MS2840A - Page 586

Anritsu MS2840A
1452 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 SCPI Device Message Details
2-576
Table 2.13-1 Device messages for Spectrum Emission Mask measurement (Cont’d)
Function Device Message
Spectrum Emission
Mask Sweep Time
[:SENSe]:SEMask:SWEep[1]:TIME <time>
[:SENSe]:SEMask:SWEep[1]:TIME?
Spectrum Emission
Mask Offset Sweep
Time
[:SENSe]:SEMask:OFFSet[1]:LIST:SWEep[1]:TIME
<time_1>,<time_2>,<time_3>,<time_4>,<time_5>,<time_6>[,<time_7>[,
<time_8>[,<time_9>[,<time_10>[,<time_11>[,<time_12>]]]]]]]]]]]
[:SENSe]:SEMask:OFFSet[1]:LIST:SWEep[1]:TIME?
Spectrum Emission
Mask Sweep Time
Auto/Manual
[:SENSe]:SEMask:SWEep[1]:TIME:AUTO ON|OFF|1|0
[:SENSe]:SEMask:SWEep[1]:TIME:AUTO?
Spectrum Emission
Mask Offset Sweep
Time Auto/Manual
[:SENSe]:SEMask:OFFSet[1]:LIST:SWEep[1]:TIME:AUTO
<switch_1>[,<switch_2>[,<switch_3>[,<switch_4>[,<switch_5>[,<swit
ch_6>[,<switch_7>[,<switch_8>[,<switch_9>[,<switch_10>[,<switch_1
1>[,<switch_12>]]]]]]]]]]]
[:SENSe]:SEMask:OFFSet[1]:LIST:SWEep[1]:TIME:AUTO?
Spectrum Emission
Mask Auto Sweep
Time Select
[:SENSe]:SEMask:SWEep[1]:TIME:AUTO:MODE NORMal|FAST
[:SENSe]:SEMask:SWEep[1]:TIME:AUTO:MODE?
Spectrum Emission
Mask Offset Auto
Sweep Time Select
[:SENSe]:SEMask:OFFSet[1]:LIST:SWEep[1]:TIME:AUTO:MODE
<mode_1>[,<mode_2>[,<mode_3>[,<mode_4>[,<mode_5>[,<mode_6>[,<mode
_7>[,<mode_8>[,<mode_9>[,<mode_10>[,<mode_11>[,<mode_12>]]]]]]]]]
]]
[:SENSe]:SEMask:OFFSet[1]:LIST:SWEep[1]:TIME:AUTO:MODE?
Spectrum Emission
Mask Detection Mode
[:SENSe]:SEMask:DETector[:FUNCtion]
NORMal|POSitive|NEGative|SAMPle|RMS|AVERage
[:SENSe]:SEMask:DETector[:FUNCtion]?
:CALCulate:SEMask:DETector[:FUNCtion]
NORMal|POSitive|NEGative|SAMPle|RMS|AVERage
:CALCulate:SEMask:DETector[:FUNCtion]?
Spectrum Emission
Mask Offset Detection
Mode
[:SENSe]:SEMask:OFFSet[1]:LIST:DETector
<mode_1>[,<mode_2>[,<mode_3>[,<mode_4>[,<mode_5>[,<mode_6>[,<mode
_7>[,<mode_8>[,<mode_9>[,<mode_10>[,<mode_11>[,<mode_12>]]]]]]]]]
]]
[:SENSe]:SEMask:OFFSet[1]:LIST:DETector?
[:SENSe]:SEMask:DETector:OFFSet[:FUNCtion]
NORMal|POSitive|NEGative|SAMPle|RMS|AVERage
Spectrum Emission
Mask Trace Point
[:SENSe]:SEMask:SWEep[1]:POINts <integer>
[:SENSe]:SEMask:SWEep[1]:POINts?
Spectrum Emission
Mask Offset Trace
Point
[:SENSe]:SEMask:OFFSet[1]:LIST:SWEep[1]:POINts
<integer_1>[,<integer_2>[,<integer_3>[,<integer_4>[,<integer_5>[,
<integer_6>[,<integer_7>[,<integer_8>[,<integer_9>[,<integer_10>[
,<integer_11>[,<integer_12>]]]]]]]]]]]
[:SENSe]:SEMask:OFFSet[1]:LIST:SWEep[1]:POINts?

Table of Contents

Other manuals for Anritsu MS2840A

Related product manuals