According to the table above, the 279 error code corresponds to
CMALARM_NCHIP_DBUF_CRC_ERR; this means that new CRC errors were seen on the
NCHIP of this particular FPC, which is FPC as per the logs.
If you do not want to convert decimal to binary and vice versa, you may use the following
shortcut:
For major alarms, the Actual Error Code = (Error Code - 1)/2, where Error Code is the
code that you get in the log message. For example, if you get the following log:
Apr 12 08:04:10 send: red alarm set, device FPC 6, reason FPC 6 Major
Errors - Error code: 257
Actual Error Code = (257-1)/2 = 128. Similarly, for minor alarms, Actual Error Code = (Error
Code)/2
Required Privilege
Level
view
Related
Documentation
Configuring an RMON Alarm Entry and Its Attributes•
• Chassis Conditions That Trigger Alarms
List of Sample Output show chassis alarms (Alarms Active) on page 1852
show chassis alarms (No Alarms Active) on page 1852
show chassis alarms (Fan Tray) on page 1852
show chassis alarms (vMX on NFX250) on page 1853
show chassis alarms (MX104 Router) on page 1853
show chassis alarms (MX2010 Router) on page 1853
show chassis alarms (MX2020 Router) on page 1853
show chassis alarms (MX10003 Router) on page 1853
show chassis alarms (MX2008 Router) on page 1853
show chassis alarms (MX960, MX480, and MX240 Routers showing Major CB
Failure) on page 1854
show chassis alarms (PTX10008 Router) on page 1854
show chassis alarms (T4000 Router) on page 1854
show chassis alarms (Unreachable Destinations Present on a T Series
Router) on page 1854
show chassis alarms (FPC Offline Due to Unreachable Destinations on a T Series
Router) on page 1855
show chassis alarms (SCG Absent on a T Series Router) on page 1855
show chassis alarms (Alarms Active on a TX Matrix Router) on page 1855
show chassis alarms (TX Matrix Plus router with 3D SIBs) on page 1856
show chassis alarms (Alarms on a T4000 Router After the enhanced-mode Statement
is Enabled) on page 1857
show chassis alarms (Backup Routing Engine) on page 1858
show chassis alarms (EX Series Switch) on page 1858
show chassis alarms (Alarms Active on the QFX Series and OCX Series
Switches) on page 1858
1851Copyright © 2017, Juniper Networks, Inc.
Chapter 42: Operational Commands