show chassis alarms node-device (Alarms Active on the QFabric System) on page 1858
show chassis alarms (Alarms Active on the QFabric System) on page 1858
show chassis alarms (Alarms Active on an EX8200 Switch) on page 1859
show chassis alarms (Alarms Active on a PTX5000 Packet Transport
Router) on page 1859
show chassis alarms (Mix of PDUs Alarm on a PTX5000 Packet Transport Router
with FPC2-PTX-P1A) on page 1859
show chassis alarms (PDU Converter Failed Alarm on a PTX5000 Packet Transport
Router with FPC2-PTX-P1A) on page 1860
show chassis alarms (No Power for System Alarm on a PTX5000 Packet Transport
Router with FPC2-PTX-P1A) on page 1860
show chassis alarms (Alarms Active on an ACX2000 Universal Access
Router) on page 1860
show chassis alarms (Active Alarm to Indicate Status of the Bad SCB Clock on MX
Series) on page 1860
showchassisalarms (Alarms active on a PTX1000 Packet Transport Router)on page1861
show chassis alarms (MX10003 Router) on page 1861
Output Fields Table 118 on page 1852 lists the output fields for the show chassis alarms command. Output
fields are listed in the approximate order in which they appear.
Table 118: show chassis alarms Output Fields
Field DescriptionField Name
Date and time the alarm was first recorded.Alarm time
Severity class for this alarm: Minor or Major.Class
Information about the alarm.Description
Sample Output
show chassis alarms (Alarms Active)
user@host> show chassis alarms
3 alarms are currently active
Alarm time Class Description
2000-02-07 10:12:22 UTC Major fxp0: ethernet link down
2000-02-07 10:11:54 UTC Minor YELLOW ALARM - PEM 1 Removed
2000-02-07 10:11:03 UTC Minor YELLOW ALARM - Lower Fan Tray Removed
show chassis alarms (No Alarms Active)
user@host> show chassis alarms
No alarms are currently active
show chassis alarms (Fan Tray)
user@host> show chassis alarms
4 alarms currently active
Alarm time Class Description
2010-11-11 20:27:38 UTC Major Side Fan Tray 7 Failure
Copyright © 2017, Juniper Networks, Inc.1852
ACX Series Universal Access Router Configuration Guide