show chassis fpc slot (T1600 Router) on page 2069
show chassis fpc pic-status (T1600 Router) on page 2069
show chassis fpc (T4000 Router) on page 2069
show chassis fpc detail (T4000 Router) on page 2070
show chassis fpc pic-status (T4000 Router) on page 2070
show chassis fpc (QFX Series and OCX Series) on page 2071
show chassis fpc detail (QFX3500 Switches) on page 2071
show chassis fpc pic-status (QFX3500 Switches) on page 2071
show chassis fpc interconnect-device (QFabric System) on page 2071
show chassis fpc interconnect-device (QFabric System) on page 2071
show chassis fpc interconnect-device detail (QFabric System) on page 2072
show chassis fpc pic-status interconnect-device (QFabric System) on page 2072
show chassis fpc pic-status node-device (QFabric System) on page 2072
show chassis fpc (PTX5000 Packet Transport Router) on page 2073
show chassis fpc detail (PTX5000 Packet Transport Router) on page 2073
show chassis fpc pic-status (PTX5000 Packet Transport Router) on page 2074
show chassis fpc (PTX10008 Router) on page 2074
show chassis fpc (ACX2000 Universal Access Router) on page 2074
show chassis fpc 0 (ACX2000 Universal Access Router) on page 2074
show chassis fpc detail (ACX2000 Universal Access Router) on page 2075
show chassis fpc pic-status (ACX2000 Universal Access Router) on page 2075
show chassis FPC 1 (MX Routers with Media Services Blade [MSB]) on page 2075
show chassis FPC 1 detail (MX Routers with Media Services Blade [MSB]) on page 2075
show chassis fpc (Node Slicing) on page 2075
show chassis fpc pic-status (Node Slicing) on page 2076
Output Fields Table 127 on page 2041 lists the output fields for the show chassis fpc command. Output
fields are listed in the approximate order in which they appear.
Table 127: show chassis fpc Output Fields
Level of OutputField DescriptionField Name
all levelsSlot number and state. The state can be one of the following conditions:
• Dead—Held in reset because of errors.
• Diag—Slot is being ignored while the FPC is running diagnostics.
• Dormant—Held in reset.
• Empty—No FPC is present.
• Offline—(PTX Series Packet Transport Routers only) One of the following
two states is displayed:
• FPC offlined due to unreachable destinations
• FPC Offlined due to degraded FPC action
• Online—FPC is online and running.
• Present—FPC is detected by the chassis daemon but either is not supported
by the current version of Junos OS or is inserted in the wrong slot. The output
also states either Hardware Not Supported or Hardware Not In Right Slot. The
FPC is coming up but not yet online.
• Probed—Probe is complete; awaiting restart of the Packet Forwarding Engine.
• Probe-wait—Waiting to be probed.
Slot or Slot State
2041Copyright © 2017, Juniper Networks, Inc.
Chapter 42: Operational Commands