EasyManua.ls Logo

Infineon TRAVEO T2G - Page 107

Infineon TRAVEO T2G
1825 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Reference Manual 002-29852 Rev. *B
Bits Name SW HW Default or
Enum
Description
16:23 AWL RW R 1 Application Watchdog Limit
The application watchdog can be disabled by
programming AWL to 0x00.
0x00-FF Maximum time after which the application has
to serve the application watchdog.
The application watchdog is incremented once each
256 NTUs.
24 EGTF RW R 0 Enable Global Time Filtering
0= Global time filtering in TTCAN Level 0,2 is disabled
1= Global time filtering in TTCAN Level 0,2 is enabled
25 ECC RW R 0 Enable Clock Calibration
0= Automatic clock calibration in TTCAN Level 0,2 is
disabled
1= Automatic clock calibration in TTCAN Level 0,2 is
enabled
26 EVTP RW R 0 Event Trigger Polarity
0= Rising edge trigger
1= Falling edge trigger
107
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers