EasyManua.ls Logo

Infineon TRAVEO T2G - 26.8.15 PWR_SSV_CTL

Infineon TRAVEO T2G
1825 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Reference Manual 002-29852 Rev. *B
26.8.15 PWR_SSV_CTL
Description:
Supply Supervision Control Register
Address:
0x40261018
Offset:
0x1018
Retention:
Retained
IsDeepSleep:
Yes
Comment:
Controls for brownout and over-voltage detectors. Fields *_VSEL and *_ACTION are only
reset by XRES/POR/BOD/OVD/OCD/HIBERNATE. Fields *_ENABLE are reset by all resets.
Default:
0x8080808
Bit-field Table
Bits 7 6 5 4 3 2 1 0
Name BODVDDA_ACTION [7:6] None [5:5] BODVDDA
_VSEL [4:4]
BODVDDD
_ENABLE
[3:3]
None [2:1] BODVDDD
_VSEL [0:0]
Bits 15 14 13 12 11 10 9 8
Name None [15:12] BODVCCD
_ENABLE
[11:11]
None [10:9] BODVDDA
_ENABLE
[8:8]
Bits 23 22 21 20 19 18 17 16
Name OVDVDDA_ACTION
[23:22]
None
[21:21]
OVDVDDA
_VSEL
[20:20]
OVDVDDD
_ENABLE
[19:19]
None [18:17] OVDVDDD
_VSEL
[16:16]
Bits 31 30 29 28 27 26 25 24
Name None [31:28] OVDVCCD
_ENABLE
[27:27]
None [26:25] OVDVDDA
_ENABLE
[24:24]
Bit-fields
Bits Name SW HW Default or
Enum
Description
0 BODVDDD_VSEL RW A 0 Selects the voltage threshold for BOD on vddd. The
BOD does not reliably monitor the supply during the
transition.
0: vddd<2.7V
1: vddd<3.0V
3 BODVDDD_ENABLE RW A 1 Enable for BOD on vddd. This cannot be disabled
during normal operation.
4 BODVDDA_VSEL RW A 0 Selects the voltage threshold for BOD on vdda. Ensure
BODVDDA_ENABLE==0 before changing this setting
to prevent false triggers.
0: vdda<2.7V
1: vdda<3.0V
6:7 BODVDDA_ACTION RW A 0 Action taken when the BOD on vdda triggers.
NOTHING 0 No action
FAULT 1 Generate a fault
RESET 2 Reset the chip
8 BODVDDA_ENABLE RW A 0 Enable for BOD on vdda. BODVDDA_ACTION will be
triggered when the BOD is disabled. If no action is
desired when disabling, firmware must first write
BODVDDA_ACTION=NOTHING in a separate write
cycle.
11 BODVCCD_ENABLE RW A 1 Enable for BOD on vccd. This cannot be disabled
during normal operation.