EasyManua.ls Logo

Infineon TRAVEO T2G - 4.13.8.9 CM4_TRCCTI_CTITRIGOUTSTATUS

Infineon TRAVEO T2G
1825 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Reference Manual 002-29852 Rev. *B
4.13.8.9 CM4_TRCCTI_CTITRIGOUTSTATUS
Description:
CTI Trigger Out Status Register
Address:
0xE0080134
Offset:
0x134
Retention:
Retained
IsDeepSleep:
No
Comment:
The CTI Trigger Out Status Register provides the status of the CTITRIGOUT outputs.
Default:
0x0
Bit-field Table
Bits 7 6 5 4 3 2 1 0
Name TRIGOUTSTATUS [7:0]
Bits 15 14 13 12 11 10 9 8
Name None [15:8]
Bits 23 22 21 20 19 18 17 16
Name None [23:16]
Bits 31 30 29 28 27 26 25 24
Name None [31:24]
Bit-fields
Bits Name SW HW Default or
Enum
Description
0:7 TRIGOUTSTATUS R RW 0 Shows the status of the CTITRIGOUT outputs.
1 = CTITRIGOUT is active
0 = CTITRIGOUT is inactive (reset).
There is one bit of the register for each trigger output.