EasyManua.ls Logo

Infineon TRAVEO T2G - 23.9.28 SCB_RX_FIFO_RD_SILENT

Infineon TRAVEO T2G
1825 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Reference Manual 002-29852 Rev. *B
23.9.28 SCB_RX_FIFO_RD_SILENT
Description:
Receiver FIFO read silent
Address:
0x40600344
Offset:
0x344
Retention:
Not Retained
IsDeepSleep:
No
Comment:
When the IP is disabled (CTRL.ENABLED is '0') or when the RX FIFO is empty, a read from
this register returns 0xffff:ffff. This register should only be used in FIFO mode (and not in EZ or
CMD_RESP modes).
Default:
0x0
Bit-field Table
Bits 7 6 5 4 3 2 1 0
Name DATA [7:0]
Bits 15 14 13 12 11 10 9 8
Name DATA [15:8]
Bits 23 22 21 20 19 18 17 16
Name DATA [23:16]
Bits 31 30 29 28 27 26 25 24
Name DATA [31:24]
Bit-fields
Bits Name SW HW Default or
Enum
Description
0:31 DATA R W Undefined Data read from the receiver FIFO. Reading a data
frame will NOT remove the data frame from the FIFO;
i.e. behavior is similar to that of a PEEK operation.
Note that when CTRL.MEM_WIDTH is '0', only
DATA[7:0] are used and when CTRL.MEM_WIDTH is
'1', only DATA[15:0] are used
A read from an empty RX FIFO sets
INTR_RX.UNDERFLOW to '1'.