Technical Reference Manual 002-29852 Rev. *B
19.5.1.14 PASS_SAR_RESULT_VALID
Description:
Channel result data register 'valid' bits
Address:
0x409001A0
Offset:
0x1A0
Retention:
Not Retained
IsDeepSleep:
No
Comment:
Default:
0x0
Bit-field Table
Bits 7 6 5 4 3 2 1 0
Name RESULT_VALID [7:0]
Bits 15 14 13 12 11 10 9 8
Name RESULT_VALID [15:8]
Bits 23 22 21 20 19 18 17 16
Name RESULT_VALID [23:16]
Bits 31 30 29 28 27 26 25 24
Name RESULT_VALID [31:24]
Bit-fields
Bits Name SW HW Default or
Enum
Description
0:31 RESULT_VALID R RW 0 If set the corresponding RESULT register is valid, i.e.
was acquired during the preceding group scan. If this
bit is low, after a group scan completed, then either the
channel is not enabled or is used as a pulse detect
channel.
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers