EasyManua.ls Logo

Infineon TRAVEO T2G - 2.3.9.6.58 CANFD_CH_TTOST

Infineon TRAVEO T2G
1825 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Reference Manual 002-29852 Rev. *B
2.3.9.6.58 CANFD_CH_TTOST
Description:
TT Operation Status
Address:
0x4052012C
Offset:
0x12C
Retention:
Retained
IsDeepSleep:
No
Comment:
Default:
0x0
Bit-field Table
Bits 7 6 5 4 3 2 1 0
Name QCS [7:7] QGTP [6:6] SYS [5:4] MS [3:2] EL [1:0]
Bits 15 14 13 12 11 10 9 8
Name RTO [15:8]
Bits 23 22 21 20 19 18 17 16
Name GFI [23:23] WGTD
[22:22]
None [21:16]
Bits 31 30 29 28 27 26 25 24
Name SPL [31:31] WECS
[30:30]
AWE
[29:29]
WFE
[28:28]
GSI [27:27] TMP [26:24]
Bit-fields
Bits Name SW HW Default or
Enum
Description
0:1 EL R RW 0 Error Level
00= Severity 0 - No Error
01= Severity 1 - Warning
10= Severity 2 - Error
11= Severity 3 - Severe Error
2:3 MS R RW 0 Master State
00= Master_Off, no master properties relevant
01= Operating as Time Slave
10= Operating as Backup Time Master
11= Operating as current Time Master
4:5 SYS R RW 0 Synchronization State
00= Out of Synchronization
01= Synchronizing to TTCAN communication
10= Schedule suspended by Gap (In_Gap)
11= Synchronized to schedule (In_Schedule)
6 QGTP R RW 0 Quality of Global Time Phase
Only relevant in TTCAN Level 0 and Level 2, otherwise
fixed to '0'.
0= Global time not valid
1= Global time in phase with Time Master
7 QCS R RW 0 Quality of Clock Speed
Only relevant in TTCAN Level 0 and Level 2, otherwise
fixed to '1'.
0= Local clock speed not synchronized to Time Master
clock speed
1= Synchronization Deviation <= SDL
120
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers

Table of Contents

Other manuals for Infineon TRAVEO T2G