Technical Reference Manual 002-29852 Rev. *B
26.8.2 PWR_LVD_STATUS2
Description:
High Voltage / Low Voltage Detector (HVLVD) Status Register #2
Address:
0x40260044
Offset:
0x44
Retention:
Retained
IsDeepSleep:
No
Comment:
Real-time status for Voltage Monitoring System
Default:
0x0
Bit-field Table
Bits 7 6 5 4 3 2 1 0
Name None [7:1] HVLVD2
_OUT [0:0]
Bits 15 14 13 12 11 10 9 8
Name None [15:8]
Bits 23 22 21 20 19 18 17 16
Name None [23:16]
Bits 31 30 29 28 27 26 25 24
Name None [31:24]
Bit-fields
Bits Name SW HW Default or
Enum
Description
0 HVLVD2_OUT R RW 0 HVLVD2 output.
0: below voltage threshold
1: above voltage threshold