Technical Reference Manual 002-29852 Rev. *B
26.8.50.11.5 MCWDT_CTR_CONFIG
Description:
MCWDT Subcounter Configuration Register
Address:
0x40268010
Offset:
0x10
Retention:
Retained
IsDeepSleep:
No
Comment:
Configuration for this MCWDT subcounter. Writes are ignored when locked (i.e. corresponding
MCWDT[i]_LOCK.WDT_LOCK<>0). This register may be written while the counter is running,
but new values may take up to 2 clk_lf cycles to take effect. MCWDT always reports the first
fault that occurs across subcounter #0 and subcounter #1 for this MCWDT, but may not report
additional faults that occur while the first is being processed.
Default:
0x0
Bit-field Table
Bits 7 6 5 4 3 2 1 0
Name None [7:6] UPPER_ACTION [5:4] None [3:2] LOWER_ACTION [1:0]
Bits 15 14 13 12 11 10 9 8
Name None [15:13] AUTO
_SERVICE
[12:12]
None [11:9] WARN
_ACTION
[8:8]
Bits 23 22 21 20 19 18 17 16
Name None [23:16]
Bits 31 30 29 28 27 26 25 24
Name DEBUG
_RUN
[31:31]
SLEEPDEEP
_PAUSE
[30:30]
None
[29:29]
DEBUG
_TRIGGER
_EN [28:28]
None [27:24]
Bit-fields
Bits Name SW HW Default or
Enum
Description
0:1 LOWER_ACTION RW R 0 Action taken if this watchdog is serviced before
LOWER_LIMIT is reached. LOWER_ACTION is
ignored (i.e. treated as NOTHING) when a debugger is
connected and/or when the corresponding processor is
in SLEEPDEEP.
NOTHING 0 Do nothing
FAULT 1 Trigger a fault. It can take up to 3 clk_lf cycles for the
fault to be transferred to the fault manager.
For LOWER_LIMIT >= 1: The action is triggered on
same edge when it meets this condition.
For LOWER_LIMIT == 0: No action is triggered.
FAULT_THEN_RESET 2 Trigger a fault. Further, trigger a system-wide reset if
the fault is not serviced and the watchdog is not
cleared within 6 clk_lf cycles. It can take up to 3 clk_lf
cycles for the fault to be transferred to the fault
manager, which gives at least 3 clk_lf cycles for
software to respond.
For LOWER_LIMIT >= 1: The action is triggered on
same edge when it meets this condition.
For LOWER_LIMIT == 0: No action is triggered.
4:5 UPPER_ACTION RW R 0 Action taken if this watchdog is not serviced before
UPPER_LIMIT is reached. The counter stops counting
when UPPER_LIMIT is reached, regardless of
UPPER_ACTION setting. UPPER_ACTION is ignored
(i.e. treated as NOTHING) when a debugger is
connected.
NOTHING 0 Do nothing
1719
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers