Technical Reference Manual 002-29852 Rev. *B
2.3.9.6.17 CANFD_CH_ILS
Description:
Interrupt Line Select
Address:
0x40520058
Offset:
0x58
Retention:
Retained
IsDeepSleep:
No
Comment:
The Interrupt Line Select register assigns an interrupt generated by a specific interrupt flag
from the Interrupt Register to one of the two module interrupt lines. For interrupt generation
the respective interrupt line has to be enabled via ILE.EINT0 and ILE.EINT1.
Default:
0x0
Bit-field Table
Bits 7 6 5 4 3 2 1 0
Name RF1LL [7:7] RF1FL [6:6] RF1WL
[5:5]
RF1NL [4:4] RF0LL [3:3] RF0FL [2:2] RF0WL
[1:1]
RF0NL [0:0]
Bits 15 14 13 12 11 10 9 8
Name TEFLL
[15:15]
TEFFL
[14:14]
TEFWL
[13:13]
TEFNL
[12:12]
TFEL
[11:11]
TCFL
[10:10]
TCL [9:9] HPML [8:8]
Bits 23 22 21 20 19 18 17 16
Name EPL [23:23] ELOL
[22:22]
BEUL
[21:21]
BECL
[20:20]
DRXL
[19:19]
TOOL
[18:18]
MRAFL
[17:17]
TSWL
[16:16]
Bits 31 30 29 28 27 26 25 24
Name None [31:30] ARAL
[29:29]
PEDL
[28:28]
PEAL
[27:27]
WDIL
[26:26]
BOL [25:25] EWL
[24:24]
Bit-fields
Bits Name SW HW Default or
Enum
Description
0 RF0NL RW R 0 Rx FIFO 0 New Message Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
1 RF0WL RW R 0 Rx FIFO 0 Watermark Reached Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
2 RF0FL RW R 0 Rx FIFO 0 Full Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
3 RF0LL RW R 0 Rx FIFO 0 Message Lost Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
4 RF1NL RW R 0 Rx FIFO 1 New Message Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
5 RF1WL RW R 0 Rx FIFO 1 Watermark Reached Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
6 RF1FL RW R 0 Rx FIFO 1 Full Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
7 RF1LL RW R 0 Rx FIFO 1 Message Lost Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
8 HPML RW R 0 High Priority Message Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
72