Technical Reference Manual 002-29852 Rev. *B
28.4.1.1.18 TCPWM_GRP_CNT_TR_OUT_SEL
Description:
Counter output trigger selection register
Address:
0x40380054
Offset:
0x54
Retention:
Retained
IsDeepSleep:
No
Comment:
Used to select internal events for output trigger generation.
Default:
0x32
Bit-field Table
Bits 7 6 5 4 3 2 1 0
Name None [7:7] OUT1 [6:4] None [3:3] OUT0 [2:0]
Bits 15 14 13 12 11 10 9 8
Name None [15:8]
Bits 23 22 21 20 19 18 17 16
Name None [23:16]
Bits 31 30 29 28 27 26 25 24
Name None [31:24]
Bit-fields
Bits Name SW HW Default or
Enum
Description
0:2 OUT0 RW R 2 Selects one of the internal events to generate the
output trigger 0. Default setting selects the terminal
count event.
OVERFLOW 0 Overflow event
UNDERFLOW 1 Underflow event
TC 2 Terminal count event (default selection)
CC0_MATCH 3 Compare match 0 event
CC1_MATCH 4 Compare match 1 event
LINE_OUT 5 PWM output signal 'line_out'
Reserved6 6 N/A
Disabled 7 Output trigger disabled.
4:6 OUT1 RW R 3 Selects one of the internal events to generate the
output trigger 1. Default setting selects the compare
match 0 event.
OVERFLOW 0 Overflow event
UNDERFLOW 1 Underflow event
TC 2 Terminal count event
CC0_MATCH 3 Compare match 0 event (default selection)
CC1_MATCH 4 Compare match 1 event
LINE_OUT 5 PWM output signal 'line_out'
Reserved6 6 N/A
Disabled 7 Output trigger disabled.