Technical Reference Manual 002-29852 Rev. *B
26.8.16 PWR_SSV_STATUS
Description:
Supply Supervision Status Register
Address:
0x4026101C
Offset:
0x101C
Retention:
Retained
IsDeepSleep:
Yes
Comment:
Status for brownout and over-voltage detectors.
Default:
0x30505
Bit-field Table
Bits 7 6 5 4 3 2 1 0
Name None [7:3] BODVCCD
_OK [2:2]
BODVDDA
_OK [1:1]
BODVDDD
_OK [0:0]
Bits 15 14 13 12 11 10 9 8
Name None [15:11] OVDVCCD
_OK [10:10]
OVDVDDA
_OK [9:9]
OVDVDDD
_OK [8:8]
Bits 23 22 21 20 19 18 17 16
Name None [23:18] OCD
_DPSLP
_REG_OK
[17:17]
OCD_ACT
_LINREG
_OK [16:16]
Bits 31 30 29 28 27 26 25 24
Name None [31:24]
Bit-fields
Bits Name SW HW Default or
Enum
Description
0 BODVDDD_OK R RW 1 BOD indicates vddd is ok. This will always read 1,
because a detected brownout will reset the chip.
1 BODVDDA_OK R RW 0 BOD indicates vdda is ok.
2 BODVCCD_OK R RW 1 BOD indicates vccd is ok. This will always read 1,
because a detected brownout will reset the chip.
8 OVDVDDD_OK R RW 1 OVD indicates vddd is ok. This will always read 1,
because a detected over-voltage condition will reset
the chip.
9 OVDVDDA_OK R RW 0 OVD indicates vdda is ok.
10 OVDVCCD_OK R RW 1 OVD indicates vccd is ok. This will always read 1,
because a detected over-over-voltage condition will
reset the chip.
16 OCD_ACT_LINREG_OK R RW 1 OCD indicates the current drawn from the linear Active
Regulator is ok. This will always read 1, because a
detected over-current condition will reset the chip.
17 OCD_DPSLP_REG_OK R RW 1 OCD indicates the current drawn from the linear
DeepSleep Regulator is ok. This will always read 1,
because a detected over-current condition will reset
the chip.
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers