Technical Reference Manual 002-29852 Rev. *B
Bits Name SW HW Default or
Enum
Description
16 OVDVDDD_VSEL RW A 0 Selects the voltage threshold for OVD on vddd. The
OVD does not reliably monitor the supply during the
transition.
0: vddd>5.5V
1: vddd>5.0V
19 OVDVDDD_ENABLE RW A 1 Enable for OVD on vddd. This cannot be disabled
during normal operation.
20 OVDVDDA_VSEL RW A 0 Selects the voltage threshold for OVD on vdda. Ensure
OVDVDDA_ENABLE==0 before changing this setting
to prevent false triggers
0: vddd>5.5V
1: vddd>5.0V
22:23 OVDVDDA_ACTION RW A 0 Action taken when the OVD on vdda triggers.
NOTHING 0 No action
FAULT 1 Generate a fault
RESET 2 Reset the chip
24 OVDVDDA_ENABLE RW A 0 Enable for OVD on vdda.
27 OVDVCCD_ENABLE RW A 1 Enable for OVD on vccd. This cannot be disabled
during normal operation.