EasyManua.ls Logo

Infineon TRAVEO T2G - 28.4.1.1.2 TCPWM_GRP_CNT_STATUS

Infineon TRAVEO T2G
1825 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Reference Manual 002-29852 Rev. *B
28.4.1.1.2 TCPWM_GRP_CNT_STATUS
Description:
Counter status register
Address:
0x40380004
Offset:
0x4
Retention:
Not Retained
IsDeepSleep:
No
Comment:
When the counter is disabled (CTRL.ENABLED = 0), then the STATUS.TR_* bit fields are
typically reset to their default values. However, there are exceptions possible in the following
cases, based on the selected input trigger via TR_IN_SEL*.*_SEL:
- If a constant '0' is selected, then a '0' is read.
- If a constant '1' is selected, then a '1' is read.
- If a general purpose trigger input 'tr_all_cnt_in' is selected which is also selected by another
counter and that counter is enabled, then the actual level of the selected trigger is read.
Default:
0x20
Bit-field Table
Bits 7 6 5 4 3 2 1 0
Name TR_STOP
[7:7]
TR
_RELOAD
[6:6]
TR_COUNT
[5:5]
TR
_CAPTUR
E0 [4:4]
None [3:1] DOWN [0:0]
Bits 15 14 13 12 11 10 9 8
Name RUNNING
[15:15]
None [14:12] LINE
_COMPL
_OUT
[11:11]
LINE_OUT
[10:10]
TR
_CAPTUR
E1 [9:9]
TR_START
[8:8]
Bits 23 22 21 20 19 18 17 16
Name DT_CNT_L [23:16]
Bits 31 30 29 28 27 26 25 24
Name DT_CNT_H [31:24]
Bit-fields
Bits Name SW HW Default or
Enum
Description
0 DOWN R RW 0 When '0', counter is counting up. When '1', counter is
counting down. In QUAD mode, this field indicates the
direction of the latest counter change: '0' when last
incremented and '1' when last decremented.
4 TR_CAPTURE0 R RW 0 Indicates the actual level of the selected capture 0
trigger.
5 TR_COUNT R RW 1 Indicates the actual level of the selected count trigger.
6 TR_RELOAD R RW 0 Indicates the actual level of the selected reload trigger.
7 TR_STOP R RW 0 Indicates the actual level of the selected stop trigger.
8 TR_START R RW 0 Indicates the actual level of the selected start trigger.
9 TR_CAPTURE1 R RW 0 Indicates the actual level of the selected capture 1
trigger.
10 LINE_OUT R RW 0 Indicates the actual level of the PWM line output
signal.
11 LINE_COMPL_OUT R RW 0 Indicates the actual level of the complementary PWM
line output signal.
1796
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers

Table of Contents

Other manuals for Infineon TRAVEO T2G