Technical Reference Manual 002-29852 Rev. *B
26.8.19 PWR_HIB_DATA
Description:
HIBERNATE Data Register
Address:
0x40261040
Offset:
0x1040
Retention:
Retained
IsDeepSleep:
No
Comment:
This register can retain information during HIBERNATE mode.
Default:
0x0
Bit-field Table
Bits 7 6 5 4 3 2 1 0
Name HIB_DATA [7:0]
Bits 15 14 13 12 11 10 9 8
Name HIB_DATA [15:8]
Bits 23 22 21 20 19 18 17 16
Name HIB_DATA [23:16]
Bits 31 30 29 28 27 26 25 24
Name HIB_DATA [31:24]
Bit-fields
Bits Name SW HW Default or
Enum
Description
0:31 HIB_DATA RW A 0 Additional data that is retained through a
HIBERNATE/WAKEUP sequence that can be used by
firmware for any application-specific purpose. Note
that waking up from HIBERNATE using XRES will
reset this register.