Technical Reference Manual 002-29852 Rev. *B
Bits Name SW HW Default or
Enum
Description
9 TCL RW R 0 Transmission Completed Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
10 TCFL RW R 0 Transmission Cancellation Finished Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
11 TFEL RW R 0 Tx FIFO Empty Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
12 TEFNL RW R 0 Tx Event FIFO New Entry Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
13 TEFWL RW R 0 Tx Event FIFO Watermark Reached Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
14 TEFFL RW R 0 Tx Event FIFO Full Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
15 TEFLL RW R 0 Tx Event FIFO Event Lost Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
16 TSWL RW R 0 Timestamp Wraparound Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
17 MRAFL RW R 0 Message RAM Access Failure Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
18 TOOL RW R 0 Timeout Occurred Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
19 DRXL RW R 0 Message stored to Dedicated Rx Buffer Interrupt
Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
20 BECL RW R 0 Bit Error Corrected Interrupt Select (not used in
M_TTCAN)
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
21 BEUL RW R 0 Bit Error Uncorrected Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
22 ELOL RW R 0 Error Logging Overflow Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
23 EPL RW R 0 Error Passive Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
24 EWL RW R 0 Warning Status Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
25 BOL RW R 0 Bus_Off Status Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
26 WDIL RW R 0 Watchdog Interrupt Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
27 PEAL RW R 0 Protocol Error in Arbitration Phase Select
0= Assign to interrupt enabled by ILE.EINT0
1= Assign to interrupt enabled by ILE.EINT1
73
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers

Table of Contents