Technical Reference Manual 002-29852 Rev. *B
Bits Name SW HW Default or
Enum
Description
8:12 HVLVD1_TRIPSEL_HT RW R 0 Threshold selection for HVLVD1 for HT products.
Detector accuracy is +/-4 percent of the nominal
values listed below. Disable the detector
(HVLVD1_EN=0) before changing the threshold.
0: rise 2.825V (nom), fall=2.8V (nom)
1: rise 2.925V (nom), fall=2.9V (nom)
2: rise 3.025V (nom), fall=3.0V (nom)
3: rise 3.125V (nom), fall=3.1V (nom)
4: rise 3.225V (nom), fall=3.2V (nom)
5: rise 3.325V (nom), fall=3.3V (nom)
6: rise 3.425V (nom), fall=3.4V (nom)
7: rise 3.525V (nom), fall=3.5V (nom)
8: rise 3.625V (nom), fall=3.6V (nom)
9: rise 3.725V (nom), fall=3.7V (nom)
10: rise 3.825V (nom), fall=3.8V (nom)
11: rise 3.925V (nom), fall=3.9V (nom)
12: rise 4.025V (nom), fall=4.0V (nom)
13: rise 4.125V (nom), fall=4.1V (nom)
14: rise 4.225V (nom), fall=4.2V (nom)
15: rise 4.325V (nom), fall=4.3V (nom)
16: rise 4.425V (nom), fall=4.4V (nom)
17: rise 4.525V (nom), fall=4.5V (nom)
18: rise 4.625V (nom), fall=4.6V (nom)
19: rise 4.725V (nom), fall=4.7V (nom)
20: rise 4.825V (nom), fall=4.8V (nom)
21: rise 4.925V (nom), fall=4.9V (nom)
22: rise 5.025V (nom), fall=5.0V (nom)
23: rise 5.125V (nom), fall=5.1V (nom)
24: rise 5.225V (nom), fall=5.2V (nom)
25: rise 5.325V (nom), fall=5.3V (nom)
others: reserved
14 HVLVD1_DPSLP_EN_HT RW R 0 Keep HVLVD1 voltage monitor enabled during
DEEPSLEEP mode. This field is only used when
HVLVD1_EN_HT==1.
15 HVLVD1_EN_HT RW R 0 Enable HVLVD1 voltage monitor. This detector
monitors vddd only. Do not change other HVLVD1
settings when enabled.
16:17 HVLVD1_EDGE_SEL RW R 0 Sets which edge(s) will trigger an action when the
threshold is crossed.
DISABLE 0 Disabled
RISING 1 Rising edge
FALLING 2 Falling edge
BOTH 3 Both rising and falling edges
18 HVLVD1_ACTION RW R 0 Action taken when the threshold is crossed in the
programmed directions(s)
INTERRUPT 0 Generate an interrupt
FAULT 1 Generate a fault
1653
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers