Technical Reference Manual 002-29852 Rev. *B
Bits Name SW HW Default or
Enum
Description
16:31 DT_LINE_COMPL_OUT RW R 0 In PWM_DT mode, this field is used to determine the
dead time before activating the complementary PWM
line output signal 'line_compl_out': amount of dead
time cycles in the counter clock domain.
In all other modes, this field has no effect.
Note: This field only exists when parameter
GRP_AMC_PRESENT for advanced motor control is
set to 1. Otherwise the dead time is only 8 bit wide and
the same dead time specified by field
DT_LINE_OUT_L is used before activating 'line_out'
and 'line_compl_out'.
1809
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers