Technical Reference Manual 002-29852 Rev. *B
Bits Name SW HW Default or
Enum
Description
9 RX_BUSY R W 0 Receiver busy.
- Set to '1' on the start of the following commands:
RX_HEADER, RX_RESPONSE.
- Set to '0' on successful completion of previous
commands or when an error is detected.
12 TX_DONE R W 0 Transmitter done:
- Set to '0' on the start of a new command.
- Set to '1' on successful completion of the following
command sequences:
- TX_HEADER.
- TX_HEADER, TX_RESPONSE.
- RX_HEADER, TX_RESPONSE.
13 RX_DONE R W 0 Receiver done:
- Set to '0' on the start of a new command.
- Set to '1' on successful completion of the following
commmand sequences:
- RX_HEADER, RX_RESPONSE.
- TX_HEADER, RX_RESPONSE.
18 TIMEOUT R W 0 Copy of INTR.TIMEOUT
19 TX_HEADER_ARB_LOST R W 0 Copy of INTR.TX_HEADER_ARB_LOST
20 TX_BIT_ERROR R W 0 Copy of INTR.TX_BIT_ERROR.
21 RX_CRC_ERROR R W 0 Copy of INTR.RX_CRC_ERROR.
22 RX_HEADER_PARITY
_ERROR
R W 0 Copy of INTR.RX_HEADER_PARITY_ERROR.
23 RX_DATA_LENGTH
_ERROR
R W 0 Copy of INTR.RX_DATA_LENGTH_ERROR.
24 TX_DATA_LENGTH
_ERROR
R W 0 Copy of INTR.TX_DATA_LENGTH_ERROR.
25 RX_OVERFLOW
_ERROR
R W 0 Copy of INTR.RX_OVERFLOW_ERROR.
26 TX_OVERFLOW_ERROR R W 0 Copy of INTR.TX_OVERFLOW_ERROR.
27 RX_UNDERFLOW
_ERROR
R W 0 Copy of INTR.RX_UNDERFLOW_ERROR.
28 TX_UNDERFLOW
_ERROR
R W 0 Copy of INTR.TX_UNDERFLOW_ERROR.
29 RX_FRAME_ERROR R W 0 Copy of INTR.RX_FRAME_ERROR.
30 TX_FRAME_ERROR R W 0 Copy of INTR.TX_FRAME_ERROR.
774
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers