EasyManua.ls Logo

Infineon TRAVEO T2G - Page 938

Infineon TRAVEO T2G
1825 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Reference Manual 002-29852 Rev. *B
Bits Name SW HW Default or
Enum
Description
22 WORK_ERR_SILENT RW R 0 Specifies bus transfer behavior for a non-recoverable
error on the FLASH macro work interface (either a
non-correctable ECC error, a FLASH macro work
interface internal error, a FLASH macro work interface
memory hole access):
0: Bus transfer has a bus error.
1: Bus transfer does NOT have a bus error; i.e. the
error is 'silent'
In either case, the erroneous FLASH macro data is
returned by the bus master interface. The erroneous
data is NOT placed in a bus master interface's cache
and/or buffer.
This field is ONLY used by CPU (and debug i.e.
SYS_AP/CM0_AP/CM4_AP) bus transfers. Non-CPU
bus transfers always have a bus transfer with a bus
error, in case of a non-recoverable error.
Note: All CPU bus masters have dedicated status
registers (CM0_STATUS and CM4_STATUS) to
register the occurrence of FLASH macro work
interface internal errors (non-correctable ECC errors
and memory hole errors are NOT registered).
Note: fault reporting can be used to identify the error
that occurred:
- FLASH macro work interface internal error.
- FLASH macro work interface non-recoverable ECC
error.
- FLASH macro work interface recoverable ECC error.
- FLASH macro work interface memory hole error.
938
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers

Table of Contents

Other manuals for Infineon TRAVEO T2G

Related product manuals