C613-50100-01 REV C Command Reference for x930 Series 817
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
IPV6 COMMANDS
IPV
6 ND MINIMUM-RA-INTERVAL
ipv6 nd minimum-ra-interval
Overview Use this command in Interface Configuration mode to set a minimum Router
Advertisement (RA) interval for a VLAN interface.
Use the no variant of this command in Interface Configuration mode to remove the
minimum RA interval for a VLAN interface.
Syntax
ipv6 nd minimum-ra-interval <seconds>
no ipv6 nd minimum-ra-interval [<seconds>]
Default The RA interval for a VLAN interface is unset by default.
Mode Interface Configuration for a VLAN interface.
Examples To set the minimum RA interval for the VLAN interface vlan2, use the following
commands:
awplus# configure terminal
awplus(config)# interface vlan2
awplus(config-if)# ipv6 nd minimum-ra-interval 60
To remove the minimum RA interval for the VLAN interface vlan2, use the
following commands:
awplus# configure terminal
awplus(config)# interface vlan2
awplus(config-if)# no ipv6 nd minimum-ra-interval 60
Related
Commands
ipv6 nd ra-interval
ipv6 nd suppress-ra
ipv6 nd prefix
ipv6 nd other-config-flag
Parameter Description
<seconds>
Specifies the number of seconds between IPv6 Router
Advertisements (RAs). Valid values are from 3 to 1350
seconds.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals