EasyManuals Logo

Allied Telesis AlliedWare Plus User Manual

Allied Telesis AlliedWare Plus
3082 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #250 background imageLoading...
Page #250 background image
C613-50100-01 REV C Command Reference for x930 Series 250
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
SYSTEM CONFIGURATION AND MONITORING COMMANDS
FINDME
TRIGGER
findme trigger
Overview When this command is enabled, the LED flashing functionality of the find-me
command is applied whenever any or all of the selected parameter conditions is
detected.
Use the no variant to remove the findme trigger function for the selected
parameter.
Syntax
findme trigger {all|loopprot|thrash-limit|qsp}
no findme trigger {all|loopprot|thrash-limit|qsp}
Default The findme trigger function is disabled.
Mode Global config
Example To enable action LED flashing for the loop protection function:
awplus# findme trigger loopprot
Related
Commands
findme
loop-protection loop-detect
storm-protection
Parameter Description
all Enable the find-me function whenever any of the listed parameter
conditions is detected
loopprot Enable the findme function whenever
the loop protection condition is detected.
thrash-limit Enable the findme function whenever
the thrash-limiting condition is detected.
qsp Enable the findme function whenever
the QoS Storm Protection condition is detected.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals