C613-50100-01 REV C Command Reference for x930 Series 250
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
SYSTEM CONFIGURATION AND MONITORING COMMANDS
FINDME
TRIGGER
findme trigger
Overview When this command is enabled, the LED flashing functionality of the find-me
command is applied whenever any or all of the selected parameter conditions is
detected.
Use the no variant to remove the findme trigger function for the selected
parameter.
Syntax
findme trigger {all|loopprot|thrash-limit|qsp}
no findme trigger {all|loopprot|thrash-limit|qsp}
Default The findme trigger function is disabled.
Mode Global config
Example To enable action LED flashing for the loop protection function:
awplus# findme trigger loopprot
Related
Commands
findme
loop-protection loop-detect
storm-protection
Parameter Description
all Enable the find-me function whenever any of the listed parameter
conditions is detected
loopprot Enable the findme function whenever
the loop protection condition is detected.
thrash-limit Enable the findme function whenever
the thrash-limiting condition is detected.
qsp Enable the findme function whenever
the QoS Storm Protection condition is detected.