C613-50100-01 REV C Command Reference for x930 Series 605
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
SPANNING TREE COMMANDS
SPANNING
-TREE ERRDISABLE-TIMEOUT INTERVAL
spanning-tree errdisable-timeout interval
Overview Use this command to specify the time interval after which a port is brought back
up when it has been disabled by the BPDU guard feature.
Use this command for RSTP or MSTP.
Syntax
spanning-tree errdisable-timeout interval <10-1000000>
no spanning-tree errdisable-timeout interval
Default By default, the port is re-enabled after 300 seconds.
Mode Global Configuration
Example
awplus# configure terminal
awplus(config)# spanning-tree errdisable-timeout interval 34
Related
Commands
show spanning-tree
spanning-tree errdisable-timeout enable
spanning-tree portfast bpdu-guard
Parameter Description
<10-1000000> Specify the errdisable-timeout interval in seconds.