C613-50100-01 REV C Command Reference for x930 Series 1789
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
PIM-SMV6 COMMANDS
IPV
6 PIM JP-TIMER
ipv6 pim jp-timer
Overview Use this command to set the PIM-SMv6 join/prune timer. Note that the value set by
the join/prune timer is the value that the device puts into the holdtime field of the
join/prune packets it sends to its neighbors.
Use the no variant of this command to return the PIM-SMv6 join/prune timer to its
default value of 210 seconds.
Syntax
ipv6 pim jp-timer <1-65535>
no ipv6 pim jp-timer [<1-65535>]
Default The default PIM-SMv6 join/prune timer value is 210 seconds.
Mode Global Configuration
Example
awplus# configure terminal
awplus(config)# ipv6 forwarding
awplus(config)# ipv6 multicast-routing
awplus(config)# ipv6 pim jp-timer 300
awplus# configure terminal
awplus(config)# no ipv6 pim jp-timer
Parameter Description
<1-65535> Specifies the Join/Prune timer value. The default value is 210
seconds.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals