C613-50100-01 REV C Command Reference for x930 Series 698
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
GVRP COMMANDS
GVRP
TIMER
To reset the GVRP join timer to its default of 20 hundredths of a second for
interface port1.0.1, enter the commands:
awplus# configure terminal
awplus(config)# interface port1.0.1
awplus(config-if)# no gvrp timer join
Related
Commands
show gvrp timer