TRIGGER COMMANDS
TYPE
STACK LINK
type stack link
Overview This command (configured to the stack) initiates the action of a pre-configured
trigger to occur when a stacking link is either activated or deactivated.
Syntax
type stack link {up|down}
Mode Trigger Configuration
Example To configure trigger 86 to activate when the stack link down event occurs, use the
commands:
awplus# configure terminal
awplus(config)# trigger 86
awplus(config-trigger)# type stack link down
Related
Commands
show trigger
trigger
type stack master-fail
Parameter Description
up Stack link up event
down Stack link down event