C613-50100-01 REV C Command Reference for x930 Series 2447
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
VIRTUAL CHASSIS STACKING (VCSTACK™) COMMANDS
SHOW
STACK RESILIENCYLINK
Related
Commands
switch provision (stack)
show stack
stack resiliencylink
switchport resiliencylink
Table 5: Parameters in the output of the show stack resiliencylink command
Parameter Description
Status The current status of the stack member’s resiliency link. Can
be one of:
• Not configured (Master or Member).
• Configured (Master only).
• Successful:
Successfully receiving healthchecks from the Active Master.
• Failed (Member only):
Not receiving any healthchecks from the Active Master.
• Stopped:
The resiliency link is configured, but is inactive. This may
occur in a Disabled Master stack, for example if the
Disabled Master Monitoring feature is not used.
Interface The name of the eth or VLAN interface that is connected to
the resiliency link.
Interface state The current status of the interface. Can be either up or
down.
Resiliency-link
port(s)
The switch port(s) the resiliency link is connected to.