fiber-monitoring interval
Overview Use this command to configure the fiber monitoring polling interval in seconds for
the port. The optical power will be read every <interval> seconds and compared
against the calculated threshold values to see if a log message or other action is
required.
Use the no variant of this command to reset the polling interval to the default (5
seconds).
Syntax
fiber-monitoring interval <2-60>
no fiber-monitoring interval
Default The interval is set to 5 seconds by default.
Mode Interface configuration mode for a fiber port.
Example To set the fiber monitoring polling interval for port 1.0.2 to 30 seconds, use the
commands:
awplus(config)# interface port1.0.2
awplus(config-if)# fiber-monitoring interval 30
To reset the fiber monitoring polling interval back to the default (5s), use the
commands:
awplus(config)# interface port1.0.2
awplus(config-if)# no fiber-monitoring interval
Related
Commands
fiber-monitoring baseline
show system fiber-monitoring
Parameter Description
<2-60> Optical power polling interval in seconds.