C613-50100-01 REV C Command Reference for x930 Series 465
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
SWITCHING COMMANDS
LOOP
-PROTECTION TIMEOUT
loop-protection timeout
Overview Use this command to specify the Loop Protection recovery action duration on an
interface.
Use the no variant of this command to set the loop protection timeout to the
default.
Syntax
loop-protection timeout <duration>
no loop-protection timeout
Default The default is 7 seconds.
Mode Interface Configuration
Usage See the “Loop Protection” section in the Switching Feature Overview and
Configuration Guide for relevant conceptual, configuration, and overview
information prior to applying this command.
Example To configure a loop protection action timeout of 10 seconds for port1.0.4, use
the command:
awplus# configure terminal
awplus(config)# interface port1.0.4
awplus(config-if)# loop-protection timeout 10
Related
Commands
loop-protection loop-detect
loop-protection action
show loop-protection
thrash-limiting
Parameter Description
<duration> The time (in seconds) for which the configured action will apply
before being disabled. This duration can be set between 0 and 86400
seconds (24 hours). The set of 0 means infinity so timeout does not
expire.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals