C613-50100-01 REV C Command Reference for x930 Series 1794
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
PIM-SMV6 COMMANDS
IPV
6 PIM REGISTER-SUPPRESSION
ipv6 pim register-suppression
Overview Use this command to configure the register-suppression time, in seconds,
overriding the default of 60 seconds.
Use the no variant of this command to reset the value to its default of 60 seconds.
Syntax
ipv6 pim register-suppression <1-65535>
no ipv6 pim register-suppression
Mode Global Configuration
Default The default PIM-SMv6 register suppression time is 60 seconds, and is restored with
the no variant of this command.
Usage Configuring this value modifies register-suppression time at the DR. Configuring
this value at the RP modifies the RP-keepalive-period value if the ipv6 pim
rp-register-kat command is not used.
Examples
awplus# configure terminal
awplus(config)# ipv6 forwarding
awplus(config)# ipv6 multicast-routing
awplus(config)# ipv6 pim register-suppression 192
awplus# configure terminal
awplus(config)# no ipv6 pim register-suppression
Parameter Description
<1-65535> Register suppression on time in seconds.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals