C613-50100-01 REV C Command Reference for x930 Series 1733
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
PIM-SM COMMANDS
IP
PIM JP-TIMER
ip pim jp-timer
Overview Use this command to set the PIM-SM join/prune timer. Note that the value the
device puts into the holdtime field of the join/prune packets it sends to its
neighbors is 3.5 times the join/prune timer value set using this command.
Use the no variant of this command to return the PIM-SM join/prune timer to its
default value of 60 seconds, which corresponds to a join/prune packet holdtime of
210 seconds.
Syntax
ip pim jp-timer <1-65535>
no ip pim jp-timer [<1-65535>]
Default The default join/prune timer value is 60 seconds.
Mode Global Configuration
Example To set the join/prune timer value to 300 seconds, use the commands:
awplus# configure terminal
awplus(config)# ip pim jp-timer 300
To return the join/prune timer to its default value of 60 seconds, use the
commands:
awplus# configure terminal
awplus(config)# no ip pim jp-timer
Parameter Description
<1-65535> Specifies the join/prune timer value. The default value is 60 seconds.