C613-50100-01 REV C Command Reference for x930 Series 464
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
SWITCHING COMMANDS
LOOP
-PROTECTION ACTION-DELAY-TIME
loop-protection action-delay-time
Overview Use this command to sets the loop protection action delay time for an interface to
specified values in seconds. The action delay time specifies the waiting period for
the action.
Use the no variant of this command to reset the loop protection action delay time
for an interface to default.
Syntax
loop-protection action-delay-time <0-86400>
no loop-protection action
Default Action delay timer is disabled by default.
Mode Interface Configuration
Example To configure a loop protection action delay time of 10 seconds on port 1.0.4, use
the commands:
awplus# configure terminal
awplus(config)# interface port1.0.4
awplus(config-if)# loop-protection action-delay-time 10
Related
Commands
show loop-protection
Parameter Description
<0-86400> Time in seconds; 0 means action delay timer is disabled.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals